Building to the wildfire code

​

This one is already here. The state wildfire code took effect in the Town at the end of June 2026 and in the county on July 1, 2026.

​

It is also the change that touches more aspects of home construction. Roof, vents, siding, eaves, decks, and the ground for a hundred feet around the building.

​

Two levels, and which one you get

Lots are rated on a Colorado Wildfire Code Map, by how a fire would likely behave on them. The rating comes down to the fuel on and around the lot and the terrain, which together predict how long the flames would run. Low intensity gets a short list of requirements. Moderate and high get the full list.

​

Most of Archuleta County is in the moderate group, so the full list is the normal case here rather than the exception.

​

If you believe your lot is rated harder than the property actually warrants, there is a process to challenge the classification with documentation from a wildfire professional. This is not a common practice yet, but it exists, and on a lot that has been thinned it can be worth looking at.

​

The short list, which applies everywhere

  • A Class A roof assembly

  • Attic and crawl space vents either tested and listed for ember resistance, or screened with eighth-inch noncombustible mesh

  • Metal valley flashing over a wide cap sheet

  • Gutters and downspouts of noncombustible material, if the house has them

  • The first five feet around the house kept clear of anything that burns

  • Retaining walls and fencing within eight feet of the house noncombustible or ignition resistant, with vinyl fencing specifically allowed

  • An address marker at the driveway entrance, readable from both directions

Covered porch with heavy timber beams and stone columns at sunset, looking out over ponderosa pines

​The full list adds the walls and more

We still frame with wood. Studs and plates are not what this is about. What has to meet the code is the outside of the wall, from the top of the foundation up to the eave.

​

Much of what people build here already qualifies. Stucco, stone and brick. Fiber cement, in lap or panel. Metal, including the products made to look like board and batten, lap siding, or log. True log and heavy timber walls still pass as they are.

​

What does not qualify on its own is ordinary wood siding, such as cedar siding. Several suppliers are now fire treating their products and labelling it for exterior use, and treated wood does qualify. These products are worth researching if you want wood or a wood look. One advantage of many of these products is they do not need to be stained or painted, and the long-term maintenance is much easier.

​

Local yards now carry fire-treated cedar, Douglas fir and thermally modified siding. When you shop, check the label. Under the code, treated wood qualifies only when it's labeled for exterior use, which means it has passed a weathering test (ASTM D2898) so the treatment holds up outdoors. Wood treated for interior use doesn't qualify, so ask your supplier for the product's paperwork before you order.

​

Some walls can get their protection from the assembly behind the siding rather than from the siding itself. A one-hour fire rated wall is one of the options under the code, and the rating has to face outward, because the fire is assumed to be outside.​

​

There is a trim allowance worth knowing about. Decoration and trim up to five percent of the wall area are exempt, not counting window and door trim. That is enough for a wood accent. It is not enough for a wood wall without the products mentioned above.

​

Then the things attached to the wall. Eaves and soffits must get covered on the underside, and fascia boards are now required. Decking has to be noncombustible or Class A rated, and composite decking needs at least a Class B rating. The space under a raised floor gets enclosed to the ground. Six inches of metal flashing goes behind the siding where the wall meets the ground, a deck or a roof. Detached buildings within fifty feet of the house follow the same wall rules.

​

Windows and doors

From the drafting table

There is a rumor that everyone will need fire rated glass or all tempered glass. This is not true. The code gives four ways to comply and one of them is an ordinary dual-pane unit. I checked with two window suppliers and neither of them sees much changing. What drives your window choice is the energy code, not the fire code.

​

​Exterior doors are tighter. Noncombustible, or solid core wood at least an inch and three quarters thick, or rated. Garage doors are exempt. Any glass in a door follows the window rule, although glass in doors is always tempered anyways.

​

The ground around the house

0 TO 5 FEET

Bare zone

rock, gravel, pavers, soil

5 TO 30 FEET

Thin it out

space plants, clear dead fuel

30 TO 100 FEET

Space crowns

trees 6 to 10 ft apart

The first five feet eliminates anything that will burn, so acceptable material is rock, gravel, concrete, pavers or bare earth. No shrubs, no bark mulch, no new trees. A mature tree already standing can stay if it is at least ten inches through at chest height, with the crown pruned back ten feet off the house. Although with construction it would be nearly impossible to leave any trees in the first five feet. I've never seen that happen in 30 years of building, especially a tree of that size.

​

From five to thirty feet, you thin things out, clear dead material, and space what is left so fire cannot run between plants. From thirty to a hundred feet the tree crowns get six to ten feet apart. Those two outer zones only apply to the moderate and high lots, which is most of them here.

​

Inside town limits a landscaping plan showing fire compliance is required with the permit application. The county does not ask for a landscape plan yet. The requirements apply either way, and the county has been handing out a defensible space sheet that explains how they intend to enforce it.

​

What the inspectors are actually allowing

From the drafting table

Two things are being allowed in the field right now that are wider than the printed code. The first is siding. Suppliers report that inspectors are accepting other sidings over a wall built as a one-hour assembly behind them. The code text names vinyl as the exception, not any siding. The second is a thickness allowance for heavy sidings, which does not appear in the code text at all.

​

Both may be sound local practice, but neither is code language. If your house design depends on one of them, get it confirmed with the building department before material gets ordered or plans are submitted.

Homes among tall pines at dusk on a forested hillside, with a golf course and ponds below

If you are remodeling instead of building

Replace a quarter or more of your roof covering and the whole roof must come up to the new standard. Replace a quarter or more of your siding and the whole wall comes under the new code, and the first five feet of ground has to comply as well.

​

An addition under 500 square feet does not trigger this code. Interior work also does not. Painting and staining do not. A parcel of 35 acres or more with one house on it, not up against a developed area, is exempt outright.​

ROOF

25% or more

replaced: whole roof to new code

SIDING

25% or more

whole wall, plus the first five feet

ADDITIONS

Under 500 sq ft

does not trigger the code

LARGE PARCELS

35+ acres

one house, not near development: exempt

What is on the market

From the drafting table

Wood siding suppliers are treating their products to meet the new wildfire code. There are metal sidings made to look like board and batten and like log, some with insulation already backing them. There are fire-rated structural panels that replace sheathing, and insulated sheathing panels that solve the energy side at the same time.

Tell me what you are building and where, and I will tell you which fire rating your lot is on and what it means for your design.

​

Related pages

The 2027 building code changes

Snow loads in Archuleta County

The energy code changes

​

Where this comes from

The 2025 Colorado Wildfire Resiliency Code, adopted by the Town of Pagosa Springs in Ordinance 1034 and by Archuleta County effective July 1, 2026. Reviewed October 2026.